description
working
when the engine is switched on, the control unit waits for the starting input
(pint) to switch to +12v; then it activates the output (53s=+12v).
if d+=0v (pin31=0v), it keeps the output high; otherwise if d+=+12v or pin
31=open, the output is deactivated after 3 sec. if the starting input switches
off (pint=open) before 3-sec time ends, the output is deactivated anyway.
when the engine is switched on, the control unit waits for the starting input
(pint) to switch to +12v; then it activates the output (53s=+12v).
if d+=0v (pin31=0v), it keeps the output high; otherwise if d+=+12v or pin
31=open, the output is deactivated after 3 sec. if the starting input switches
off (pint=open) before 3-sec time ends, the output is deactivated anyway.
power supply voltage v
12v
max load
5 a