Description WORKING
As long as the starting signal (+50) remains Open, the output 53S remains Open. The first time that
the starting signal switches high (start attempt), after the control unit starts being power supplied,
the signal in W frequency from the alternator is tested:
- if f < 350Hz +/- 10Hz, the output 53S remains in the same state (ON) as long as
Tcount = 38 sec +/-2sec ends or if T switches to Open
- if f >= 350Hz +/-10Hz the output 53S is switched to Open and the starting
procedure is immediately stopped.
In any case, when T switches to Open, the output 53S is switched to Open too.
A second start (T high) is not allowed, unless the key signal is switched off.
POWER SUPPLY VOLTAGE V
12V
Components for access platforms telescopic - cranes
Trucks tractors - trailers
Fire fighting - rescue vehicles
Motorcycles - quad components
Electric vehicles - golf cart
Can-bus boat global control system
Ambulances - emergency vehicles