description
working
if the frequency of the signal on the pin 31 is less than 370hz = > the
output is reset (53s=open)
if the frequency of the signal on the pin 31 is more than 370hz = > the
output is active (53s=+12v)
power supply voltage v
12v
max load
5 a
relay type
tachymetric
frequency
370 hz
APPLICATIONS
Components for access platforms telescopic - cranes