tension load cell 5 tons for longitudinal tension weight measurement. typical application is the weight measurement on winches, tilting mechanism, generic weight scales. it is possible to have alternative mechanical dimensions for specific applications.
| load (kg.) | std | atex | a | b | c | d | e | f |
|---|
| 500 |
yes |
yes |
100 |
36 |
200 |
26 |
23 |
134 |
| 7500 |
yes |
yes |
100 |
41 |
200 |
29 |
35 |
130 |
| 10000 |
yes |
yes |
100 |
50 |
220 |
36 |
42 |
136 |
| 15000 |
yes |
yes |
130 |
58 |
250 |
42 |
47 |
156 |
| 20000 |
yes |
yes |
130 |
70 |
250 |
52 |
47 |
156 |
capacities fs emax
100 .. 20000 kg
zero balance output
± 0.02 mv/v
input resistance
400 ± 20 ohm
output resistance
350 ± 2 ohm
insulation resistance
> 5 g ohm
combined error
<± 0.03% fs
not repeatability
<± 0.015% fs
creep 30 min.
<± 0.030% fs
effetto della temperatura sullo zero @ 5 °c
<± 0.02% fs
effetto della temperatura sulla sensibilita' @ 5 °c
<± 0.005% fs
compensated temperature range
-10 .. +40 °c 14 .. 104°f
operating temperature
-20 .. +70 °c -4 .. +158 °f
maximum safe load
150% fs
connection length mm detail
5 m - 6 x 0.14 mmq; / 5 m - 6 x 0.35 mmq
mean time to failure mttf
1093 years